Atlas of details · Other nodes

Sealed joint between panels

D.01Precast concrete wall panel
123456

How this node works

All the watertightness of a prefab façade lives in the joints. The line works in two stages: an outer sealant takes the brunt of the rain, but the real seal is the inner gasket, kept dry; between them an open decompression chamber equalises the wind pressure so water is not driven through, and a small drain weeps out what little gets in.

Key points

  • Panel A
  • Panel B
  • External sealant
  • Decompression chamber
  • Inner gasket
  • Drainage

Conceptual, language-neutral drawing for study and orientation — not an execution drawing. Dimensions and verifications belong to the designer.

Sealed joint between panels — Precast concrete wall panel | Architheca