Atlas of details · Ground connection & foundations
Igloo unit
How this node works
The plastic dome units rest on the blinding and act as permanent formwork: concrete fills the legs to form little columns, and the slab is cast over the domes. The continuous void beneath is the ventilated space; a barrier under it stops damp and radon.
Key points
- R.C. slab + mesh
- Dome (igloo)
- Air space
- Cast leg (between domes)
- Damp / radon barrier
- Blinding
Conceptual, language-neutral drawing for study and orientation — not an execution drawing. Dimensions and verifications belong to the designer.