Continuity over the support

D.02Composite steel-deck floor
123456

How this node works

Over an internal support the slab is continuous: top (negative-moment) reinforcement is placed across the support to tie the two spans and control cracking, while the connectors keep the composite action.

Key points

  • Collaborating slab
  • Continuity reinforcement (negative)
  • Deck (left span)
  • Deck (right span)
  • Support beam
  • Connectors

Conceptual, language-neutral drawing for study and orientation — not an execution drawing. Dimensions and verifications belong to the designer.