Bearing and continuity

D.01Lattice-girder precast floor (predalles)
123456

How this node works

The plank bears on the beam with a minimum length; cast monolithically with the topping, the support is closed with continuity (negative-moment) reinforcement that ties the floor over the beam and controls cracking.

Key points

  • Bearing beam / ring beam
  • Plank (predalle) bearing
  • Minimum bearing length
  • Collaborating topping
  • Continuity reinforcement (negative moment)
  • Anchored girder

Conceptual, language-neutral drawing for study and orientation — not an execution drawing. Dimensions and verifications belong to the designer.