UNI 11367

UNI 11367: the acoustic class of dwellings

In forceAcusticaNorma tecnica (UNI/EN/ISO)Volontaria● Verified

Summary

TAV. 00

The standard that classifies the acoustic quality of a dwelling requirement by requirement — insulation between units, facade, impact noise, services — into four classes, from I to IV, with on-site verification. It is voluntary and does not replace the legal requirements of D.P.C.M. 5/12/1997; in public procurement the building CAM requires at least class II. Current edition: UNI 11367:2023. Protected technical standard: its logic is described.

Scope of application

TAV. 01

It applies to the acoustic classification of dwellings, except for some types. It is read together with D.P.C.M. 5/12/1997 (legal passive acoustic requirements) and Law 447/1995 (framework law); in public procurement it is called in by the building CAM (D.M. 24/11/2025, criterion 2.3.10) and, for schools, by art. 206-sexies of D.Lgs. 152/2006.

How this standard works

TAV. C

It defines the criteria to measure and assess certain acoustic requirements of buildings — airborne sound insulation between units, facade insulation, impact noise, services noise — and, on that basis, classifies the dwelling for each requirement into four classes, from I (the best) to IV; where possible, it also gives a summary evaluation with a single index. It is voluntary and does not replace the legal minimum requirements.

A class for silence

As with energy, noise too has a class. UNI 11367 — 'Acustica in edilizia - Classificazione acustica delle unità immobiliari - Procedura di valutazione e verifica in opera', the acoustic classification of building units with its evaluation procedure and on-site verification — sets the criteria to measure and assess certain acoustic requirements of buildings and, on that basis, classifies the dwelling into four classes, from I, the best, to IV. It is voluntary, but some public acts make it a requirement in public procurement: the Minimum Environmental Criteria for buildings and, for schools, the Environmental Code.

What is assessed

It is assessed requirement by requirement, on the individual technical elements that the building CAM lists — horizontal and vertical partitions, facades, building services: airborne sound insulation between different units, facade insulation, impact noise, noise from continuously and intermittently operating services. For each requirement the standard assigns a class to the whole dwelling (except for some types) and, where possible, also gives a summary evaluation, with a single index. They are two different pieces of information: whoever promises or asks for a class must say whether it means one requirement or the overall index.

The acoustic classes of dwellings
Class I
Class II
Class III
Class IV
← highest qualitylowest quality →

Voluntary, but no substitute for the law (the hard case)

Here is the point not to confuse. The passive acoustic requirements of buildings are set by D.P.C.M. 5/12/1997, which implements the framework law on noise pollution (Law 447/1995). UNI 11367 is something else: a four-class classification, distinct from the legal limits. A public act shows it: the building CAM requires class II 'without prejudice to the legal requirements' of the decree, and provides for the case in which the two require different performance for the same indicator — then the stricter one must be achieved. 'Compliant' and 'class I' are not synonyms.

Where public acts call it in

The acts that cite UNI 11367
ActWhat it requires
D.M. 24/11/2025 (building CAM), Annex 1, criterion 2.3.10for the individual technical elements — partitions, facades, services — at least class II of tables 1 and 2, and the 'good performance' values of table B.1 of Annex B; for hospitals and care homes the 'higher performance' of table A.1 of Annex A; for indoor acoustic comfort, schools excluded, Annex C; for schools UNI 11532-2. The requirements of D.P.C.M. 5/12/1997 are unaffected
D.M. 23/06/2022 (2022 building CAM), § 2.4.11at least class II of table 1; for hospitals and care homes the 'higher performance' of Annex A and the 'good performance' of Annex B; for indoor spaces, schools excluded, Annex C; for schools UNI 11532-2. The requirements of D.P.C.M. 5/12/1997 are unaffected
D.M. 11/10/2017 (2017 building CAM), § 2.3.5.6at least class II; the 'higher performance' of Annex A for hospitals, care homes and schools; the 'good performance' of Annex B; acoustic design and a test report with on-site measurements
D.Lgs. 152/2006, art. 206-sexies(1)in tenders for energy efficiency, renovation or construction of schools, pending regional technical rules, materials and solutions suited to the values of the acoustic descriptors of UNI 11367:2010 and UNI 11532:2014
Editorial summary of the text of the acts; the tables and values of the standard are not given.

In works on existing buildings the 2025 CAM applies the same requirements when the renovation, total or partial, acts on the elements separating indoors from outdoors or adjoining units, or creates new partitions or new services. In ordinary and extraordinary maintenance it instead requires the existing passive acoustic requirements to be improved, unless the elements already meet the requirements or architectural constraints, bans in building and local regulations or technical impossibility rule it out — to be shown in a report by the acoustics technician —, and in any case maintained.

Verified on the finished building

The class is not certified on paper alone: on-site verification is in the very title of the standard. The building CAM turn it into two documents: at design stage a predictive acoustic calculation report, at the final conformity check a test report based on on-site acoustic measurements, both by a qualified acoustics technician (Law 447/1995, art. 2(6), and D.Lgs. 42/2017). Between calculation and measurement lies workmanship: a poorly executed joint or service penetration is what the measurement brings out.

Why it matters

UNI 11367 gives acoustic comfort a language: it makes it declarable and comparable, requirement by requirement. In public procurement it is already a requirement: with the building CAM, class II becomes the minimum level of the individual technical elements, and hospitals, care homes and indoor spaces have their own references in the annexes of the standard. Between private parties it remains voluntary: what counts is what the contract or the specification states.

Key points

TAV. K
  • It classifies a dwelling's acoustic quality requirement by requirement, in four classes from I (the best) to IV; current edition 2023 (protected standard).
  • Requirements: insulation between units, facade insulation, impact noise, services noise; where possible, also an overall summary index.
  • It is voluntary and does not replace the legal requirements of D.P.C.M. 5/12/1997: in public contracts the building CAM requires class II, without prejudice to those requirements.
  • 'Legally compliant' and 'class I' are not the same: where class and decree diverge, the CAM imposes the stricter performance.
  • The class is verified by measurements on the finished building: under the CAM, predictive calculation at design stage and a test report with on-site measurements.

Materials concerned

TAV. M

Frequently asked questions

TAV. Q
What is the acoustic class of a dwelling?

The class that UNI 11367 assigns to the dwelling for each acoustic requirement — insulation between units, facade insulation, impact noise, services noise —, on four levels from I, the best, to IV; where possible, the standard also gives an overall summary index.

Is acoustic classification mandatory?

No, the standard is voluntary; what is mandatory are the passive acoustic requirements of D.P.C.M. 5/12/1997. It becomes a requirement in public contracts applying the building CAM (at least class II) and, for schools, in the tenders of art. 206-sexies of D.Lgs. 152/2006.

Is a 'compliant' home in class I?

Not necessarily: compliance with the legal requirements and the class are two different measures, which the CAM keeps apart — it requires class II 'without prejudice' to the legal requirements, and the stricter performance where the two diverge for the same indicator.

How is the class determined?

With the measurement and evaluation criteria of the standard, requirement by requirement, and with on-site verification. Under the CAM a predictive calculation is needed at design stage and a test report with on-site acoustic measurements at the final check, by a qualified acoustics technician.

Why is workmanship so important?

Because a poorly executed detail (a joint, a service penetration) can lower the class: acoustics depends greatly on execution.

Which edition should be cited?

The current edition is UNI 11367:2023, in force since 26 January 2023, which superseded the 2010 one. The acts are not aligned: art. 206-sexies of D.Lgs. 152/2006 still cites UNI 11367:2010, the 2025 CAM the undated designation. In a specification the edition must be written in full.

And for schools?

The 2025 CAM refers to UNI 11532-2 for the passive acoustic requirements and indoor acoustic comfort of schools; art. 206-sexies of D.Lgs. 152/2006 cites UNI 11367:2010 and UNI 11532:2014 together in tenders for school buildings.

Glossary

TAV. G
Classe acustica
Level assigned by UNI 11367 to the dwelling for each acoustic requirement, on four classes from I (the best) to IV.
Isolamento ai rumori aerei
Ability of a partition to reduce the passage of airborne sound (voices, TV).
Rumore da calpestio
Noise transmitted through the structure by footsteps and impacts on the floor.
Rumore degli impianti
Sound produced by the building's systems (plumbing, lifts, ventilation).
Verifica in opera
Measurement of acoustic performance on the finished building, not only in design.
Valutazione sintetica
Single index with which UNI 11367, where possible, sums up all the requirements of a dwelling; it sits alongside the class of each requirement.
Requisiti acustici passivi
The acoustic performance of the building's elements — partitions, facades, services — set by law by D.P.C.M. 5/12/1997.
Tecnico competente in acustica
Professional qualified under Law 447/1995 (art. 2(6)) and D.Lgs. 42/2017; under the CAM signs the predictive report and the test report with on-site measurements.