Skip to main content
ARCHITHECA.
Compliance NavigatorBetaTime MachineBetaSpecification CheckerBetaBlueprintComing soonState ExamBeta
MaterialsBuilding systems
RegulationsConstruction processesLexiconThe network
Journal
ARCHITHECA.
TOOLS
BlueprintCompliance NavigatorTime MachineSpecification CheckerState Exam
MATTER
MaterialsBuilding systems
KNOWLEDGE
RegulationsConstruction processesLexiconThe networkJournal

Newsletter

The journal, now and then.

New pieces, materials and notes from the field. No spam, unsubscribe anytime.

By subscribing you accept the Privacy Policy.

ARCHITHECA.

Material library and journal of architecture, building technique and design culture.

Explore

HomeJournalBlueprintMaterialsBuilding systemsSearch

Knowledge

RegulationsConstruction processesLexiconThe networkGeneral indexState Exam

Info

Method & AboutPropose a themePrivacy & LegalContact

© 2026 Architheca — All rights reserved

Independent editorial project
← All regulations
● Open text · reproducible
D.M. 03/08/2015

Technical fire-prevention standards (Italian Fire Prevention Code)

In forceSicurezza in caso d'incendioLegge/DecretoCogente● Verified

Summary

TAV. 00

Approves the technical fire-prevention standards, introducing a performance-based, flexible approach (horizontal technical rule) to fire-safety design. It defines strategies, measures and performance levels. Conceived in 2015 as an alternative to the traditional technical rules, since 20 October 2019 it is no longer one: for activities without a traditional vertical rule, the Code is the only route.

Scope of application

TAV. 01

It applies to the activities subject to fire-prevention controls listed in Annex I of D.P.R. 151/2011. For activities without a traditional vertical technical rule, the Code has been the sole reference since 20 October 2019, by effect of the Ministerial Decree of 12 April 2019 which removed the so-called 'double track'. Where a traditional technical rule still exists, the relationship between the two texts is set by their respective transitional provisions: it must be checked activity by activity.

In depth

TAV. A

Ministerial Decree of 3 August 2015 marked the most important shift in recent Italian fire-prevention history: moving from a system of dozens of separate technical rules, each with its own language, to a single, coherent body. It is not a mere formal reorganisation — it changes the very way fire safety is designed.

The paradigm shift: from prescriptive to performance-based

The traditional model was prescriptive: the rule imposed precise solutions (distances, sizes, materials) and the designer applied them to the letter. The Code adds a performance-based approach (fire safety engineering): safety objectives are set and one demonstrates, with engineering methods, that the chosen solution meets them. It is the same performance logic that governs the Eurocodes in the structural field.

The design path in brief
  1. 01
    Identifying the activityOne checks whether and how the activity falls under Presidential Decree 151/2011 and which Vertical Technical Rule, if any, applies.
  2. 02
    Risk assessmentThe risk profiles for life (Rvita), property (Rbeni) and environment (Rambiente) are determined.
  3. 03
    Choosing the fire-safety strategyPerformance levels are assigned to the individual fire measures according to the risk profiles.
  4. 04
    Conforming or alternative solutionOne adopts the conforming solution (predefined by the Code) or an alternative solution, proving its equivalence with performance methods.

How the Code is structured: RTO + RTV

The Code is organised into a Horizontal Technical Rule (RTO) — the general part valid for all civil activities — and Vertical Technical Rules (RTV) that adapt the principles to specific types. Fire safety is broken down into measures, each graded on increasing performance levels.

Some of the fire-safety measures (strategy)
MeasurePurpose
Reaction to firelimit the materials' contribution to fire growth
Fire resistanceensure load-bearing capacity and compartmentation over time
Compartmentationconfine the fire within bounded volumes
Evacuationensure safe escape of occupants
Detection and alarmdetect the fire early and warn
Smoke and heat controlkeep escape routes usable and aid rescue
Editorial summary for information: the Code defines a structured set of fire-safety measures, each with several performance levels.
Worked example

In a building with combustible internal finishes, the reaction-to-fire measure translates into requiring a given reaction-to-fire class for those products. This is where the Code links directly to materials: the required class refers to the European classification (see the materials linked to this entry).

UPDATE

The text of the Code is no longer the 2015 one, and two decrees from 2019 matter more than the rest. The Ministerial Decree of 12 April 2019 removed the 'double track': since 20 October 2019, activities without a traditional vertical technical rule are designed under the Code alone, which went from being an alternative to being the only route. The Ministerial Decree of 18 October 2019 then wholly replaced Annex 1, that is the horizontal rule itself. Vertical Technical Rules have been added since, and keep being added. Before any design use, always check the current consolidated text on the official source.

Key points

TAV. K
  • Performance-based approach (fire safety engineering) alongside the prescriptive one
  • Structured into fire measures: reaction and resistance to fire, evacuation, detection, smoke control
  • Since 20 October 2019 it is no longer an alternative: the Decree of 12/04/2019 removed the 'double track' and that of 18/10/2019 replaced the horizontal rule
  • Applies to activities subject to fire-prevention controls (Presidential Decree 151/2011)

Processes involved

TAV. P
PRC.02Ventilated FacadePRC.01External Thermal Insulation (ETICS)

Building systems that apply it

TAV. S
S-52Glulam timber roofS-05Ventilated façadeS-39Metal ventilated façadeS-42Timber ventilated façadeS-25Stone ventilated façadeS-01External Thermal Insulation Composite System (ETICS)S-32Curtain wall (continuous façade)S-22Quartz-hardened industrial concrete floor

State-exam tracks that call it into play

TAV. E

Where this rule shows up in past architect qualification exams — study the rule, not just the theme.

2026 · I sess.Two briefs: a dance school with a small theatre, a house-museum with an artist's atelierUniversità della Campania "Luigi Vanvitelli" (Aversa)2025 · I sess.Social housing in a district under regenerationPolitecnico di Milano2025 · II sess.Reuse of a disused industrial complex on the edge of the Parco SudPolitecnico di Milano2024 · II sess.Two briefs: a small civic building on a sloping lot, a low-rise high-density block with a roof gardenUniversità della Campania "Luigi Vanvitelli" (Aversa)

Frequently asked questions

TAV. Q
Is the performance-based method mandatory?

No. The Code lets the designer choose: conforming (prescriptive) solutions predefined by the Code, or alternative solutions proven equivalent via performance methods. The performance route is an option, not an obligation.

What is the difference between RTO and RTV?

The RTO (Horizontal Technical Rule) is the general part, valid for all civil activities. RTVs (Vertical Technical Rules) adapt those principles to specific building types (car parks, healthcare, hotels, schools, residential buildings, etc.).

Does the Code apply to all buildings?

It applies to the activities subject to fire-prevention controls listed in Annex I of D.P.R. 151/2011, not to all buildings. Mind one point that many sources still report as it stood in 2015, though: for activities without a traditional vertical technical rule the Code is no longer optional. The Ministerial Decree of 12 April 2019 removed the 'double track', and since 20 October 2019 those activities are designed under the Code alone. Where a traditional rule still exists, the relationship between the two texts is set by their respective transitional provisions.

How is the Code organised (sections G, S, V)?

Into sections: G (general: terms, design methodology, risk profiles), S (fire-safety strategy: the prevention and protection measures with their performance levels) and V (vertical technical rules for specific activities).

Glossary

TAV. G
RTO
Horizontal Technical Rule: the general part of the Code, applicable to all civil activities.
RTV
Vertical Technical Rule: specific provisions for a given activity type (e.g. car parks, healthcare facilities).
Profilo di rischio
Parameter summarising an activity's risk to life (Rvita), property (Rbeni) and environment (Rambiente), guiding the choice of performance levels.
Soluzione conforme
A design solution predefined by the Code which, if adopted, automatically meets the safety objective without further demonstration.
Soluzione alternativa
A design solution different from the conforming one, allowed if the designer proves its equivalence to the safety objectives using performance methods.

Details

Body
Ministero dell'Interno
Type
Legge/Decreto
Binding
Cogente
Level
Nazionale
Year
2015
In force
18 Nov 2015
Read the official text (free) ↗
gazzettaufficiale.it ›
Editorial status: Verified

Radar

Watch this regulation

We’ll email you if its editorial or in-force status changes. No spam.

By continuing you accept the Privacy Policy.

Embed the badge