Università di Bologna · 2018 · Prova pratica

Three single-family houses: terraced, on a steep slope, with a patio

I session · section A · Tre temi a sceltaIn review

What the track asks

A sealed envelope with three alternative practical-exam themes (Section A, 5 hours): three takes on the single-family house, each set by a different site constraint, with the linked first written test (justify the choices, the construction system and the structural sizing). All three share the same rooms (living with kitchen or kitchenette, one bath on the entrance floor to be shown accessible to disabled users, a store, a double bedroom, a twin room, a second bath; at least one bath with a window and one with a tub), and require stating areas, window sizes and compliance with daylight/ventilation ratios. THEME 1 — on a flat 8.5×22 m north-south lot, a house built to the boundary on the east and west sides (blind facades, to allow the adjoining terraces) and keeping minimum distances north and south; entrance and garage off the north street, the garage in a detached body at least 3 m away; maximum eaves height 8.5 m. THEME 2 — on a steep site (7 m drop between the uphill north side and the downhill south), a lot projecting 18×16 m with access from the uphill road, the preferred view toward the valley and a rock slope of good bearing: massing no more than 3 m above the access-road level, minimum distances from the boundaries except the north, a covered parking space on the entrance floor. THEME 3 — on a flat 22×22 m lot, a patio house with an inner court of at least 6×6 m, a garage and a maximum eaves height of 8.5 m. Shared deliverables: 1:100 plans with external works, 1:100 section and elevations, and the construction detail of the ground and roof nodes showing attention to energy containment (1:20).

Required drawings

Shared by the three themes: ground-floor and whole-lot plan with external works 1:100; first-floor plan 1:100 (both with minimal furniture); at least one significant section 1:100; elevations (north and south, or two significant ones) 1:100; construction detail of the ground-attachment and roof/vertical-closure nodes showing attention to energy-containment rules, 1:20. Room areas, window sizes and daylight/ventilation ratios must be stated. Linked first written test: justify the choices, the construction system and the structural sizing.

Regulations this track calls into play

Editorial anchoring: the rules a well-prepared candidate should have in hand for this theme, each with its current status.

D.P.R. 380/2001Consolidated Building Act (Testo Unico Edilizia)In forceD.M. 1444/1968Mandatory limits of density, height, distance between buildings and urban standardsIn forceD.M. 236/1989Technical requirements for the accessibility of private buildingsIn forceD.Lgs. 192/2005Implementation of Directive 2002/91/EC on the energy performance of buildingsIn forceD.M. 26/06/2015Minimum energy-performance requirements for buildings (the 'minimum requirements decree')In forceD.M. 17/01/2018Technical Standards for Construction (NTC 2018)In force

This theme, across the archive

The same brief seen by theme: every other past exam that asked for it, and the norm kit they share.

Single-family houseCollective housing

Full official text at the university source ↗

Practice this track in the exam room

All tracks

Editorial summary for study orientation — not the official text and not legal advice. Formats change: check the current ministerial ordinance and your university.

Three single-family houses: terraced, on a steep slope, with a patio — Università di Bologna · 2018 I session · Prova pratica | Architheca