Summary

TAV. 00

Sets the dimensional and hygiene minimums that make a room habitable: clear internal height, floor area of rooms and dwellings, natural light and ventilation, bathroom fittings, heating and acoustic protection. Together with the municipal building code, this is the rule that decides whether a space can be called a dwelling.

Scope of application

TAV. 01

Applies to rooms intended for habitation, in new buildings and in works that alter their layout. It is the technical benchmark against which fitness for use is assessed under Presidential Decree 380/2001. Municipal building codes and regional laws may impose stricter requirements, not looser ones. Statutory derogations for buildings of cultural interest, and those introduced for the existing stock, remain in force.

In depth

TAV. A

It is a half-page decree from 1975, and it remains the rule that most often decides whether a residential scheme stands up. It says nothing about structure or energy: it says how tall a room must be, how large, how much light and air it must receive. These are the figures an architect checks before anything else, because getting them wrong means designing a space that can never be declared fit for habitation.

The minimums the decree sets
QuantityPrescribed minimum
Clear internal height, habitable rooms2.70 m
Clear internal height, corridors, bathrooms, storage2.40 m
Height in mountain municipalities above 1000 m2.55 m
Bedroom for one person9 sqm
Bedroom for two people14 sqm
Living room14 sqm
Studio dwelling, one person (services included)28 sqm
Studio dwelling, two people (services included)38 sqm
Habitable area per occupant, first four14 sqm
Openable window area1/8 of the floor area
Average daylight factor2%
Editorial summary of the minimums set by the decree. Municipal building codes may impose stricter values.

The most misunderstood point is the light and ventilation ratio. The decree asks not for one thing but for two, and both must be satisfied: the openable window area must not fall below one eighth of the floor area, and the average daylight factor must not fall below two per cent. The first is a geometric check done in a minute; the second is a lighting calculation that depends on orientation, external obstructions, room depth and glazing type. A deep room facing a narrow courtyard can meet the one-eighth rule and still fail the two per cent.

The articles on services are equally operational. Bathrooms may be internal, but then mechanical extraction is required and open-flame appliances are absolutely prohibited: this is why a boiler cannot sit in a windowless bathroom. A cooking area attached to the living room must open widely onto it and have forced extraction over the hob, which legitimises the open kitchen but not a kitchen shut into a recess without extraction. And at least one bathroom per dwelling must have a WC, a bidet, a bath or shower and a washbasin.

The decree has been substantially amended only once, by the Health Ministry decree of 9 June 1999, which added a derogation for rooms in buildings within mountain communities undergoing building rehabilitation, where the building has typological features worth conserving and the design still guarantees adequate hygiene conditions. Derogations for buildings of cultural interest protected under the Cultural Heritage Code also remain in force.

Key points

TAV. K
  • Minimum clear internal height 2.70 m in habitable rooms, 2.40 m in corridors, bathrooms and storage
  • Openable window area no less than 1/8 of the floor area and average daylight factor of at least 2%
  • Single bedroom at least 9 sqm, double at least 14 sqm, living room at least 14 sqm
  • Bathrooms without an external opening require mechanical extraction, and open-flame appliances are prohibited
  • Studio dwelling: at least 28 sqm for one person and 38 sqm for two, services included

State-exam tracks that call it into play

TAV. E

Where this rule shows up in past architect qualification exams — study the rule, not just the theme.

2026 · I sess.Two briefs: a dance school with a small theatre, a house-museum with an artist's atelierUniversità della Campania "Luigi Vanvitelli" (Aversa)2025 · I sess.Social housing in a district under regenerationPolitecnico di Milano2025 · II sess.Reuse of a disused industrial complex on the edge of the Parco SudPolitecnico di Milano2025 · II sess.Change of use of a former courtyard carpentry workshop into housingPolitecnico di Torino2025 · I sess.New residential building on a corner lot, in dialogue with a listed buildingPolitecnico di Torino2025 · I sess.Three themes: terraced house, detached villa, town hall with squareUniversità "G. d'Annunzio" Chieti-Pescara2025 · II sess.Two themes: two-family villa with courtyard, small block on pilotisUniversità "G. d'Annunzio" Chieti-Pescara2025 · II sess.A villa for an artist on the Trieste CarsoUniversità degli Studi di Trieste2025 · II sess.A two-family house around an internal courtyard in a peri-urban settingUniversità della Campania "Luigi Vanvitelli" (Aversa)2025 · I sess.Single-family house in an agricultural zone (new build)Università di Bologna2025 · I sess.Completing a house on an already-started frameUniversità di Bologna2025 · II sess.nZEB two-family house in a consolidated urban area in ModenaUniversità di Bologna2024 · I sess.Two themes: temporary housing for the Besta hospital, recovery of a courtyard farmsteadPolitecnico di Milano2024 · I sess.Two themes: merging two dwellings, a demountable kiosk in a historic squarePolitecnico di Torino2024 · I sess.Two themes: riverside residential buildings, multifunctional public buildingPolitecnico di Torino2024 · II sess.Two themes: mixed craft-residence building, an office/production buildingPolitecnico di Torino2024 · I sess.Three themes: rural residence, exhibition space, media libraryUniversità "G. d'Annunzio" Chieti-Pescara2024 · II sess.Four themes: a Francigena centre, a lighthouse restoration, a historic house, a Sorano recovery planUniversità degli Studi di Firenze2024 · I sess.Four themes: a house on the Francigena, tower ruins, a Belvedere pavilion, an urban blockUniversità degli Studi di Firenze2024 · II sess.Two themes: a detached house on a lot, the urban recovery of a square in TriesteUniversità degli Studi di Trieste2024 · I sess.A bioclimatic tower house on a sloping lotUniversità della Campania "Luigi Vanvitelli" (Aversa)2024 · II sess.Two briefs: a small civic building on a sloping lot, a low-rise high-density block with a roof gardenUniversità della Campania "Luigi Vanvitelli" (Aversa)2024 · II sess.Single-family house in an agricultural zoneUniversità di Bologna2019 · II sess.Three spaces for the town: an artist's house, a fortress lift, a terraced hotelUniversità di Bologna2018 · II sess.Three themes: a coastal observatory, “growing houses”, the Pinerolo market canopyUniversità degli Studi di Genova2018 · I sess.Three single-family houses: terraced, on a steep slope, with a patioUniversità di Bologna2018 · II sess.Three themes: an atelier in a former depot, a porticoed infill, a student houseUniversità di Bologna2017 · I sess.Three residential types: terraced, block, patio housesUniversità di Bologna2016 · II sess.Three themes: attic reuse, a retail complex, housing on a slope in ImperiaUniversità degli Studi di Genova2016 · I sess.Three residential building types: terraced, in-line, gallery-accessUniversità di Bologna2015 · I sess.One site, three projects: a library, a housing complex, an urban study on the ex-AMT depotUniversità degli Studi di Genova2014 · I sess.Three themes: housing at Sestri Levante, a farm-stay to recover, a residential implementation planUniversità degli Studi di Genova2013 · I sess.Three themes: a town hall from a villa, a farm-stay house in the Apennines, an accessible flatUniversità degli Studi di Genova2013 · II sess.Three themes: a shop-and-housing block, a food market, a brewery in a harbour warehouseUniversità degli Studi di Genova2013 · II sess.Three themes: housing over shops, a neighbourhood culture centre, a public sports areaUniversità della Campania "Luigi Vanvitelli" (Aversa)2013 · I sess.House-workshop: a dwelling and a work space over a duplexUniversità della Campania "Luigi Vanvitelli" (Aversa)2012 · I sess.Three themes: terraced houses, a gallery-access apartment building, restoration of a Romanesque churchUniversità della Campania "Luigi Vanvitelli" (Aversa) · in review2007 · I sess.An in-line residential building with shops on the ground floorUniversità della Campania "Luigi Vanvitelli" (Aversa)

Frequently asked questions

TAV. Q
Can a room 2.50 m high be habitable?

Not in new construction on level ground: the minimum is 2.70 m, and 2.40 m applies only to corridors, hallways, bathrooms, WCs and storage. Exceptions are mountain municipalities above one thousand metres, where it drops to 2.55 m, and the existing stock, for which the Salva Casa opened a derogation down to 2.40 m under precise conditions. When in doubt, always check the municipal building code as well, which may be stricter.

Is meeting the 1/8 ratio enough to comply?

No. The decree sets two simultaneous requirements: openable window area no less than one eighth of the floor, and an average daylight factor no less than two per cent. The first is checked as a ratio of areas, the second with a lighting calculation accounting for orientation, external obstructions, room depth and glass transmission. In narrow courtyards and deep rooms it is the second requirement that fails.

Did the Salva Casa abolish the 2.70 metres?

No, and the distinction matters. The 1975 decree still governs new construction. Decree-Law 69/2024 introduced into the Building Act a derogation for rehabilitating the existing stock, allowing dwellings with heights down to 2.40 m and reduced areas to be declared fit for use, subject to conditions and a professional certification. It is a targeted derogation, not a new general rule.

Is a windowless bathroom allowed?

Yes, provided it has mechanical extraction in place of an external opening. The decree adds a prohibition that is often forgotten at design stage: in bathrooms without an external opening, open-flame appliances may not be installed. That is the technical reason why an open-chamber boiler cannot be placed in an internal bathroom.

Glossary

TAV. G
Altezza interna utile
Distance between the finished floor and the finished ceiling of a room, measured net of suspended ceilings and floor finishes.
Superficie finestrata apribile
The part of the window that can actually be opened for air change: it coincides neither with the glazed area nor with the structural opening.
Fattore medio di luce diurna
Ratio between the average internal illuminance of a room and the external illuminance under overcast sky, expressed as a percentage.
Alloggio monostanza
Dwelling in which living, cooking and sleeping areas are not separated by walls: the decree sets its minimum area including services.
Posto di cottura
Meal-preparation area attached to the living room: it must open widely onto it and have forced extraction over the hob.